Quality Policy
Career Opportunities
Contact Us
Directions to ISS
Comments & Suggestions
Gregorio Weber Award
Internal Use
02/20/2010: ISS Announces 2010 Gregorio Weber Award Winner
02/28/2009: ISS Announces 2009 Gregorio Weber Award Winner
02/02/2008: ISS Announces 2008 Gregorio Weber Award Winner
06/06/2007: ISS Awarded NIH Grant
03/03/2007: ISS Announces 2007 Gregorio Weber Award Winner
News Archive
Fluorescence Products
Alba FCS: Fluorescence Correlation SpectrometerAlba FLIM: Fluorescence Lifetime Imaging
PC1: Photon Counting Spectrofluorimeter
K2: Multifrequency Cross-Correlation Phase and Modulation Fluorometer
ChronosFD: Frequency-Domain Lifetime Spectrometer
ChronosBH: Time-Domain Lifetime Spectrometer
Modular Components
Phoenix: SLM Upgrade Packages
Accessories
Software
Request Literature for Fluorescence Products
Biomedical Products
OxiplexTSImagent
Request Literature for Biomedical Products
Fluorescence Lifetime Standards
Lifetime Data of Selected Fluorophores
Excitation and Emission Wavelengths of Fluorophores
Fluorescent Probes Data Table
Fluorescent Proteins Table
Fluorescence Standards for LEDs and Laser Diodes
Application & Technical Notes
Measurement Examples
Selected Publications
Laboratories & Societies
Measurement of Fluorescence Quantum Yields on ISS Instrumentation Using Vinci
Yevgen Povrozin and Ewald Terpetschnig
ISS, Inc.
Introduction
The luminescence quantum yield is given as the ratio of the number of photons emitted to the number of photons absorbed by the sample:

The quantum yield Q can also be described by the relative rates of the radiative and non-radiative pathways, which deactivate the excited state:

where kr and knr correspond to radiative and non-radiative processes, respectively.
In this equation, Σknr describes the sum of the rate constants for the various processes that compete with the emission process. These processes include photochemical, and dissociative processes including other, less well characterized changes that result in a return to the ground state with simultaneous dissipation of the energy of the excited state into heat. These latter processes are collectively called non-radiative transitions and two types have been clearly recognized: intersystem crossing and internal conversion. Intersystem crossing related to the radiationless spin inversion of a singlet state (S1) in the excited state into a triplet state (T1).
While measurements of the “absolute” quantum yield do require more sophisticated instrumentation [1], it is easier to determine the “relative” quantum yield of a fluorophore by comparing it to a standard with a known quantum yield. Some of the most common standards are listed in table below:
| Quantum Yield [Q.Y.] Standards | Q.Y. [%] | Conditions for Q.Y. Measurements | Excitation [nm] | Ref. |
| Cy3 | 4 | PBS | 540 | 2 |
| Cy5 | 27 | PBS | 620 | 2 |
| Cresyl Violet | 53 | Methanol | 580 | 3 |
| Fluorescein | 95 | 0.1 M NaOH, 22oC | 496 | 3 |
| POPOP | 97 | Cyclohexane | 300 | 3 |
| Quinine sulfate | 58 | 0.1 M H2SO4, 22oC | 350 | 3 |
| Rhodamine 101 | 100 | Ethanol | 450 | 4 |
| Rhodamine 6G | 95 | Water | 488 | 4 |
| Rhodamine B | 31 | Water | 514 | 4 |
| Tryptophan | 13 | Water, 20oC | 280 | 3 |
| L-Tyrosine | 14 | Water | 275 | 3 |
Table 1. List of common standards for fluorescence quantum yield measurements.
The quantum yields of these compounds are mostly independent of the excitation wavelength, allowing these standards to be used wherever they display useful absorption. This is what Vavilov discovered already in 1927 [5]. Exceptions to Vavilov’s Law can occur [6].
Determination of the relative quantum yield is generally accomplished by a comparison of the wavelength-integrated intensity of the unknown sample with the standard. There are two approaches for relative quantum yield measurements: The “one point” method, where the quantum yield is calculated, using only one emission value for the sample and one for the standard is fast, but not always reliable.
The second approach is the comparative method described by Williams et al. [7]. It is more time consuming yet providing higher accuracy by comparing the integrated fluorescence intensity and the absorption for sample and reference.
Instrumentation
The fluorescence intensity measurements were performed on PC1™, the photon-counting fluorescence spectrometer from ISS.
The PC1™ is a sensitive, compact, computer-controlled photon-counting spectrofluorometer designed for applications in physical chemistry, biochemistry, physiology, neurochemistry, molecular biology, environmental analysis, and immunoassay research. Vinci, a comprehensive and flexible fluorescence spectroscopy analysis software package, enables instrument control and data acquisition directly from the PC computer.
The PC1™ can be fully upgraded to the K2™ Multifrequency Phase Fluorometer for fluorescence and phosphorescence lifetime measurements with picosecond resolution. A large variety of light sources and accessories are available for a wide range of applications.

Experimental Conditions
Quantum yield standards should be chosen to ensure maximum overlap of the absorption and emission between sample and reference.
Instruments Setup. Once the spectrofluorometer parameters are adjusted and set, they should be kept unchanged during the entire measurement.
Cuvettes. In order to minimize the error for measured absorption values, it is advisable to use cuvettes with optical path lengths of 20 mm - 50 mm. However, 10 mm cuvettes are acceptable.
Optical density. To avoid inner filter effects, the optical density must be below 0.1 at the excitation wavelength.
Measurement Procedure
- Absorption spectrum of the solvent.
- Absorption spectrum of the sample.
- Subtract absorption spectrum of the solvent from the absorption spectrum of the sample.
- Determine the optical density of the sample at the anticipated excitation wavelength.
- Take the emission spectrum of the solvent.
- Take the emission spectrum of the sample.
- Subtract the emission spectrum of solvent from the emission spectrum of sample. Use the corrected emission spectrum and calculate the area under the curve.
- Repeat the same routine for the quantum yield standard.
How to improve the precision of quantium yield measurements
Use cuvettes with extended optical path lengths (20 mm - 50 mm), which allow more accurate measurement of lower concentrations.
Prepare solutions with optical densities ranging from 0.1 to 0.01, and calculate the quantum yield using the "gradient method" described below.
Calculation
The relative quantum yield is generally determined by comparing the wavelength-integrated intensity of an unknown sample to that of a standard. The quantum yield of the unknown sample is calculated using:

where Q is the quantum yield, I is the integrated intensity, n is the refractive index, and OD is the optical density. The subscript R refers to the reference fluorophore of known quantum yield.
However, a more accurate method to determine quantum yields is to prepare solutions with optical densities between 0.1 to 0.01, and to calculate the quantum yield using the gradients determined for the sample and the reference. In this case quantum yield can be calculated using:

where Grad is the gradient obtained from the plot of the integrated fluorescence intensity vs. optical density (see below). Vinci analysis software enables to carry out these procedures and to calculate the quantum yields using the gradient method.
Measurement of Quantum Yields Using Vinci
Upon completion of the recording of the emission spectra with Vinci - Instrument and Experiment Control switch to Vinci Analysis. Click on File -> New and the following New Data Set dialog box will appear; here the X and Y-axes are defined; choose Custom and press Edit List. This will allow you to fill in the X values (Optical Density).

After all X values are filled in, press OK and another New Data Set dialog box will come up. The next step is to input the Y data (Integrated Fluorescence Intensity): click on Data and proceed with adding the Y-data values.

After this step, switch to Visualization and you will obtain the following screen:

The above Integrated Fluorescence Intensity vs. Optical Density graph was obtained from the experimental data. To obtain the quantum yield of the sample it is necessary to determine the gradient of this curve: Press Fitting -> Custom model, then click on Fitting model and enter the following equation
Grad * x
in line 2 below the #----- here goes your definition ------ line and press Fit!

This will produce the fit with the numerical value for the gradient:

The numerical value of the gradient of the quantum yield standard - GradR = 2.219 x 108 – is then used for the calculation of the quantum yield of the sample.
The same steps need to be repeated to obtain the sample(s) gradient(s):

Grad = 5.170 x 107 (for the sample)
If we assume that the quantum yield of the Reference (QR) is 1, and the refractive index of sample and reference to be the same, which is true for measurements in the same solvent system, then the quantum yield of the sample (Q) is:
Q = 1*(5.170*107 / 2.219*108) = 0.23 (23%)
References:
- C.V. Bindhu, S.S. Harilal, G.K. Varier, R.C. Issac, V.P.N. Nampoori and C.P.G Vallabhan, Measurement of the absolute fluorescence quantum yield of rhodamine B solution using a dual-beam thermal lens technique. J. Phys. D: Appl. Phys. 29, 1074, 1996.
- R.B. Mujumdar, L.A. Ernst, S.R. Mujumdar, C.J. Lewis, A.S. Waggoner, Cyanine dye labeling reagents: sulfoindocyanine succinimidyl esters. Bioconj Chem 4, 105-111, 1993.
- J.R. Lakowicz, Principles of Fluorescence Spectroscopy, 2nd Ed., Kluwer Academic/Plenum Publishers, New York, London, Moscow, Dordrecht, 1999.
- D. Magde, G.E. Rojas, and P. Seybold, Solvent Dependence of the Fluorescence Lifetimes of Xanthene Dyes. Photochem. Photobiol. 70, 737, 1999.
- Vavilov, S.I., Z. Physik, 42, 311, 1927.
- D.M. Jameson et al. in Basic Concepts in Fluorescence, Fluorescence: Basic Concepts, Principles Aspects and some Anecdotes, Methods Enzymol. 360, 1 – 43, 2003.
- 7. A.T.R. Williams, S.A. Winfield and J.N. Miller, Relative fluorescence quantum yields using a computer controlled luminescence spectrometer. Analyst, 108, 1067, 1983.