Quality Policy
Career Opportunities
Contact Us
Directions to ISS
Comments & Suggestions
Gregorio Weber Award
03/03/2007: ISS Announces 2007 Gregorio Weber Award Winner
02/18/2006: ISS Announces 2006 Gregorio Weber Award Winner
09/01/2005: ISS Achieves ISO 9001:2000 Certification
01/05/2005: ISS Announces a New Version of OxiplexTS™
12/23/2004: ISS Introduces Light Emitting Diodes (LEDs) for the Study of Proteins
News Archive
Fluorescence Products
Alba FCS: Fluorescence Correlation SpectrometerAlba FLIM: Fluorescence Lifetime Imaging
PC1: Photon Counting Spectrofluorimeter
K2: Multifrequency Cross-Correlation Phase and Modulation Fluorometer
Chronos: Frequency-Domain Lifetime Spectrometer
ChronosBH: Time-Domain Lifetime Spectrometer
Modular Components for Building Spectrofluorometers
Phoenix: SLM Upgrade Packages
Software
Request Literature for Fluorescence Products
Biomedical Products
OxiplexTSImagent
Request Literature for Biomedical Products
Fluorescence Lifetime Standards
Lifetime Data of Selected Fluorophores
Excitation and Emission Wavelengths of Fluorophores
Fluorescent Probes Data Table
Fluorescence Standards for LEDs and Laser Diodes
Application & Technical Notes
Measurement Examples
Selected Publications
Laboratories & Societies
PC1™
Photon Counting Spectrofluorimeter

PC1™ is a very sensitive, compact, computer-controlled Photon Counting
Spectrofluorimeter designed for applications in physical chemistry, biochemistry, physiology, neurochemistry,
molecular biology, environmental analysis, and immunoassay research.
For a comprehensive list of PC1™ users, click here.
Measurements (Steady-State Fluorescence)
- Corrected excitation and emission spectra
- Excitation-emission matrices
- Excitation polarization spectra
- Polarization (anisotropy) measurements at fixed wavelengths
- Millisecond kinetics in photon counting mode
- Dual-wavelength ratiometric excitation or emission
Five key features make the PC1™ Photon Counting Spectrofluorimeter the most modern instrument in its class:
Sensitivity
The compact design optimizes the light path so that the sample compartment receives the maximum possible excitation light. The end result of the compact design is an instrument with an outstanding ability to measure fluorophores with very low quantum yields.
Full Automation
Instrument control and data acquisition are PC-controlled through Vinci. All active instrument components and integrated external devices are displayed on the Instrument Control Window in Vinci. From here, the user has direct remote control over all devices and accessories.
Integration of External Devices
PC1™ has the capability to integrate external devices such as a stopped flow accessory, temperature bath, flash lamp, pressure pump, and a titrator. Any of these devices can be directly controlled through Vinci.
Data Reduction Management
Vinci - Multidimensional Fluroescence Spectroscopy software acquires data in ASCII format for maximum compatability with other software packages. Data files can be stored directly on other workstations connected to a local area network.
Upgradability
PC1™ is fully upgradable to a time-resolved fluorometer to acquire time-resolved fluorescence and phosphorescence measurements with picosecond resolution. A variety of light sources and other accessories are available for a broad range of applications.