Quality Policy
Career Opportunities
Contact Us
Directions to ISS
Comments & Suggestions
Gregorio Weber Award
Internal Use
06/06/2007: ISS Awarded NIH Grant
03/03/2007: ISS Announces 2007 Gregorio Weber Award Winner
02/18/2006: ISS Announces 2006 Gregorio Weber Award Winner
09/01/2005: ISS Achieves ISO 9001:2000 Certification
01/05/2005: ISS Announces a New Version of OxiplexTS™
News Archive
Fluorescence Products
Alba FCS: Fluorescence Correlation SpectrometerAlba FLIM: Fluorescence Lifetime Imaging
PC1: Photon Counting Spectrofluorimeter
K2: Multifrequency Cross-Correlation Phase and Modulation Fluorometer
Chronos: Frequency-Domain Lifetime Spectrometer
ChronosBH: Time-Domain Lifetime Spectrometer
Modular Components for Building Spectrofluorometers
Phoenix: SLM Upgrade Packages
Software
Request Literature for Fluorescence Products
Biomedical Products
OxiplexTSImagent
Request Literature for Biomedical Products
Fluorescence Lifetime Standards
Lifetime Data of Selected Fluorophores
Excitation and Emission Wavelengths of Fluorophores
Fluorescent Probes Data Table
Fluorescence Standards for LEDs and Laser Diodes
Application & Technical Notes
Measurement Examples
Selected Publications
Laboratories & Societies
Differences between Optical Tomography and fMRI
A magnetic resonance imaging (MRI) examination is not an easy undertaking for every person. Let us look at the external conditions: the patient is enclosed by the narrow tunnel while the instrument is generating a rattling noise and the patient is instructed not to move while the machine is taking measurements, which may take up to twenty minutes. In a word, the examination is not conducive to relaxation. These limitations of fMRI are severe when the subjects to examine are children or infants, adolescents with attention deficit hyperactive disorder and when the patient is confused and feels claustrophobic.
Imagent™ does not have these limitations. Fiber optics sensors are placed on the head of the patient who can be sitting on a chair in a friendly environment and move freely; no noise is generated by the instrument. The instrument also frees the scientist to conduct extended neural analysis studies of brain activity during movement – research that is impossible or impractical with fMRI. The operator of the instrument can be sitting at a distance from the subject or close to the subject. Fibers can be as long as 10 meters, which opens several interesting options for investigational purposes.
In some applications the researcher wants to monitor the brain activity for an extended time period; when using Imagent™ there is no time limitation as the electrodes can be left in place even for several hours.
Comparison of the signals measured by Imagent™ and by fMRI
Functional MRI (fMRI) is a powerful technique for the study of cerebral activation. It does not have any penetration limits, provides high spatial resolution and allows event related measurements. Most studies of cerebral hemodynamics are based on the use of blood oxygen level dependent (BOLD) signal. The increase of the BOLD signal is typically interpreted as a decrease in the concentration of deoxy-hemoglobin (washout) due to the increase supply of oxy-hemoglobin.
Although the technique is widely used, it also suffers some severe limitations. The BOLD signal depends not only on the deoxy-hemoglobin concentration changes but also on changes in the total blood volume. In addition, a positive BOLD signal can be due to an increase in the water fraction in the measured volume. As more than one variable contributes to the signal, fMRI does not provide the biochemical specificity needed to distinguish physiological parameters.
Imagent™ measures changes in both oxy- and deoxy-hemoglobin concentration; therefore providing the researcher with two simultaneous parameters unequivocally related to the brain hemodynamics. The instrument is also capable of directly detecting the neuronal activity that manifests through the fast signal (event related optical signal - EROS). NIRS techniques have the inherent capability to distinguish physiological parameters.