Alba FCS™ Specifications

Instrument Features

  • Computer controlled selection of the confocal pinhole size
  • Computer controlled alignment of the confocal pinhole and optics
  • Computer controlled positioning of the objective (z-axis)
  • Computer-controlled XYZ microscope stage
  • Single-photon or multi-photon excitation
  • One channel or dual-channel data acquisition
  • Avalanche photodiodes or cooled photomultiplier tubes detectors

Measurements

  • Fluorescence Correlation Spectroscopy (single- and cross-correlation)
  • Photon Counting Histogram (PCH)
  • Polarization measurements
  • Particle tracking
  • Scanning FCS

Parameters That Can Be Derived Using Vista-FCS and Confocal Imaging Microscopy Software:

  • Autocorrelation and Cross-Correlation Functions:
    Vista resolves 1 or 2 species using:
    • Diffusion coefficient
    • Diffusion time
    • Sample concentration
    • Triplet state decay time constant
    • Triplet function
    • Flow rate
    • Size of excitation volume
    • Number of molecules

  • Photon Counting Histogram (PCH):
    Vista resolves 1 or 2 species using:
    • Number of molecules
    • Molecular brightness

Optical Unit

  • Light Sources:
    • Single photon lasers housed in a laser launcher with computer-control of beam expander, laser intensity and shutter; or,
    • Multi-photon excitation with computer-control of beam expander, laser intensity and shutter
  • Optics:
    • An adapted Nikon microscope with lens revolver for objectives, bottom and side ports and computer-controlled XY-stage for sample slides and for 384-well plates.
    • Available for Leica, Olympus and Zeiss inverted and upright microscopes
    • Objectives:
      • Air objectives with 20X, 40X, 60X magnification and 1.5-8.1 working distances
      • Oil immersion objectives, 1.4 NA and 60X (standard); other aperture available
      • Water immersion objectives,1.2 NA 60X (standard), with coverslip correction (for 0.15-0.18 coverslip); other apertures available
    • Dichroic Filters:
      • For single-photon excitation: 1-, 2-, 3-band filters
      • For multi-photon excitation
    • Polarizer:
      • Cube beam splitter, wavelength range: 450-1100 nm; extinction ratio: 10,000:1 at +/- 3degrees
  • Stage:
    • Large distance movement (100x100x10 mm)
      • Stepper motor-controlled XYZ stage
    • Micro-distance movements
      • XYZ piezo-controlled stage, 100x100x50 µm with 5 nm step resolution.
  • Sample Holders
    • Microwell plates
    • Petri dishes
    • Coverslip
  • Light Detectors:
    • Both detectors feature pre-amplifier discriminators with TTL output avalanche photodiodes (APDs)
    • Cooled photomultiplier tubes

Software: Vista-FCS and Confocal Imaging Microscopy

  • Operating System
    • Windows ME/XP
  • Data Acquisition Modes
    • Time mode
    • Photon mode
  • Statistical Functions Utilized for Data Analysis
    • Autocorrelation function
    • Cross-correlation function
    • Photon Counting Histogram (PCH)
  • Single Set and Global Fitting Models for Fitting
    • Autocorrelation and cross-correlation functions
      Vista resolves 1 or 2 species using:
      • 2D- or 3D-Gaussian PSF
      • 3D-Gaussian-Lorentzian PSF
      • One-photon excitation
      • Two-photon excitation
      • Presence of flow
      • Input of user-defined equation

    • Photon Counting Histogram (PCH)
      Vista resolves 1 or 2 species using:
      • 2D- or 3D uniform
      • 2D- or 3D-Gaussian PSF
      • 3D-Gaussian-Lorentzian PSF
      • One-photon excitation
      • Two-photon excitation

Instrument

  • Computer
    • Intel-type CPU, Windows XP operating system
  • Power Requirements
    • Universal power input: 110-240 V, 50/60 Hz, 400 VAC
  • Dimensions
    • 885 mm (L) x 600 mm (W) x 330 mm (H)
  • Weight
    • 40 kg